http://www.flowmetermaker.com
Home > Products > LD Electromagnetic Flow Meter > Digital Water Electromagnetic Flowmeter

Digital Water Electromagnetic Flowmeter

    Payment Type: L/C,T/T,D/P,Money Gram,Western Union
    Incoterm: FOB,CFR,CIF
    Min. Order: 1 Set/Sets
    Delivery Time: 2 Days
Basic Info

Model No.: LD

Application: Slurry ,waste Water,water,acid Or Alkaline Liquid

Size: DN10-DN2200mm

Signal: Pulse ,analog ,RS485,RS232

Lining: Rubber,PTFE,FLS,F46,FEP,F4

Electrod: 316L,HC,HB,Ti,Ta,Pt

Power Supply: 24VDC,220VDC

Additional Info

Packaging: export packing,wooden case for digital water flow meter

Brand: Tianwei

Transportation: Ocean,Land,Air

Product Description

Digital water Electromagnetic Flow Meter

electromagnetic flow meters are intended for fluid measurement in most industries including water, wastewater, food and beverage, pharmaceutical and chemical.
There are two basic components of electromagnetic flow meter:
1) The Detector, which includes the flow tube, isolating liner and measuring electrodes, and
2) The Converter, which is the electronic device responsilbe for signal processing, flow calculation, display and output signals.


1>electromagnetic water flow meter for salt solutions/beer/slurry/ beverage , electromagnetic beverage flow meter

2>flange,triclover,clamp,thread connection,etc
3>4-20mA,pulse,HART,485

electromagnetic salt solutions/beer/slurry flowmeter is an inductive apparatus to measure the flow volume of electric medium in the tube.The flowmeter composes of sensor and converter.The electromagnetic flowmeter can not only be read straightly but also output 4-20mA current signal for purpose of memory,adjustment and control,It is extensively used in industry technology and administration department such as chemical industry,environmental protection,medicine,paper making and water supply ,etc.



Technical Features:

  • Not affected by the change of the fluid condition such as density, viscosity, temperature, pressure and conductivity, and the signal output of inductive voltage is linear to average velocity, therefore it has a high accuracy of measurement.
  • No obstacle parts in the meter tube so that no extra pressure loss; no movable parts, so meter has long service life.
  • Short straight pipe required, only 5D for upstream and 3D for downstream due to inductive voltage signal which is the average value in the cross-section of the pipe.
  • Only liner and electrode contact to the fluids, choose proper material of liner and electrode to prevent it from corrosion to ensure meter long operation life.
  • MCU and SMT technology used in converter to make it has high performance, high accuracy, low power consumption, stable zero point, easy parameter setting, dot-matrix display for total and instantaneous flowrate, velocity and percentage of flowrate.
  • Two-direction measurement for forward and reverse.


Technical Specifications:

  • Size: DN 10 ~ DN 2000
  • Medium: Conductive liquid, slurry
  • Medium Temperature: E grade∠60oC, H grade∠180 oC
  • Conductivity: ≥ 5 μS/cm
  • Accuracy: ±0.5%, ±1.0%
  • Repeatability: ±0.1%
  • Rated Pressure: 0.25, 0.6, 1.0, 1.6, 4.0MPa (or specified by customer)
  • Display: Instantaneous flowrate, total flow, velocity, flowrate percentage with back light
  • Signal Output: 4~20mA current output, pulse output, RS-485, Hart, Profibus-DP
  • Power Supply: 220VAC, 24VDC
  • Converter Type: Compact, remote
  • Protection Grade: IP67/ IP68
  • Explosion Proof: Ex deibmb IIC T3~6
  • Velocity: 0.3 ~ 12m/s( 0.1 ~ 15m/s as required)
  • Liner: Chloroprene Gum (DN50 ~ DN3200) / Polyurethane (DN25 ~ DN500) / F4 (PTFE) (DN25 ~ DN1600) / F46 (FEP) (DN10~DN200) / PFA (DN10~300)
  • Flowing Direction: Forward, Reverse
  • Electrode Material: 316L, Pt, Ta, Ti, HB, HC, WC
  • Electrode Type: Standard fixed type, blade type
  • Electrode Number: 4 ~ 6 pcs
  • Flange Material: SS / CS
  • Alarm (normal open): Empty, excitation, upper / lower limit
  • Ambient: Temperature: -25 ~ +60oC, Humidity: 5 ~ 90%
  • Communication: RS-485 / Hart / Profibus-DP
Pparatus selection
DN Usual full range flow volume selection(m3/h) Integration Partial installation
weights(KG) weights (KG)
10 0.16,0.2,0.25,0.3,0.4,0.5,0.6,0.8,1.0,1.2,1.6,2.0,2.5 6 4
15 0.4,0.5,0.6,0.8,1.0,1.2,1.6,2.0,2.5,3.0,4.0,5.0,6.0 6 4
20 0.6,0.8,1.0,1.2,1.6,2.0,2.5,3.0,4.0,5.0,6.0,8.0,10.0,12.0 6 4
25 1.0,1.2,1.6,2.0,2.5,3.0,4.0,5.0,6.0,8.0,10.0,12.0,14.0,16.0 7 5
32 1.6,2.0,2.5,3.0,4.0,5.0,6.0,8.0,10.0,12.0,14.0,16.0,20.0,25.0 9 7
40 2.5,3.0,4.0,5.0,6.0,8.0,10.0,12.0,14.0,16.0,20.0,25.0,30.0,40.0 10 8
50 4.0,5.0,6.0,8.0,10.0,12.0,14.0,16.0,20.0,25.0,30.0,40.0,50,60,70 12 10
65 ,6.0,8.0,10.0,12.0,14.0,16.0,20.0,25.0,30.0,40.0,50,60,80,100,120 17 15
80 10.0,12.0,14.0,16.0,20.0,25.0,30.0,40.0,50,60,80,100,120,160 17 15
100 16.0,20.0,25.0,30.0,40.0,50,60,80,100,120,160,200,250 22 20
125 25.0,30.0,40.0,50,60,80,100,120,160,200,250,300,400 24 22
150 40.0,50,60,80,100,120,160,200,250,300,400,500,600 35 33
200 60,80,100,120,160,200,250,300,400,500,600,800,1000 45 43
250 100,120,160,200,250,300,400,500,600,800,1000,1200;1600 84 82
300 120,160,200,250,300,400,500,600,800,1000,1200;1600,2000,2500 102 100
350 200,250,300,400,500,600,800,1000,1200;1600,2000,2500,3000 123 121
400 250,300,400,500,600,800,1000,1200;1600,2000,2500,3000,4000 147 145
450 300,400,500,600,800,1000,1200;1600,2000,2500,3000,4000,5000 212 210
500 400,500,600,800,1000,1200;1600,2000,2500,3000,4000,5000,6000 229 207
600 600,800,1000,1200;1600,2000,2500,3000,4000,5000,6000,10000 252 250
700 800,1000,1200;1600,2000,2500,3000,4000,5000,6000,10000,12000 352 350
800 1000,1200;1600,2000,2500,3000,4000,5000,6000,10000,12000,16000 462 460
900 1200;1600,2000,2500,3000,4000,5000,6000,8000,10000,12000,16000 550
1000 1600,2000,2500,3000,4000,5000,6000,8000,10000,12000,16000;20000 680




Looking for ideal Electromagnectic Water Flow Meter Manufacturer & supplier ? We have a wide selection at great prices to help you get creative. All the Magnetic Water Flow Meter are quality guaranteed. We are China Origin Factory of Dirty Water Waste Water Flowmeter. If you have any question, please feel free to contact us.

Product Categories : LD Electromagnetic Flow Meter

Email to this supplier
  • *Subject:
  • *Messages:
    Your message must be between 20-8000 characters
Communicate with Supplier?Supplier
Grace Liu Ms. Grace Liu
What can I do for you?
Contact Supplier